A building inspection checklist walks an inspector through a property system by system, from the parking lot to the roof, and records what passed, what failed and what needs a repair. Workyard's version is an annual building inspection checklist: a yearly condition check of an existing building's grounds, roof, interior, fire and life safety equipment, and mechanical, electrical and plumbing systems.

Facility managers, property managers, building owners and the contractors who maintain buildings for them use it. It also works as a walkthrough before a purchase or lease, or before handing a renovated building back to an owner.

What is a building inspection?

A building inspection is a documented check that a building is safe, sound and meets the rules that apply to it. There are two different kinds, and it pays to know which one you are doing.

  • Code inspections are done by the local building department at set stages of a permitted job, such as footings, foundation, framing, rough-in and final. The inspector checks the work against the code your jurisdiction has adopted, usually a version of the International Building Code or International Residential Code with local amendments. A city's own list, like this municipal residential inspection checklist, shows what its inspectors look for at each stage.
  • Condition inspections are run by the owner, a facility manager or a contractor on a building already in use. Nobody hands out a permit; the goal is to find problems before they get expensive or dangerous.

The annual template is the second kind. For inspections during construction, use the construction inspection checklist, and for stage checks before the city inspector arrives, the foundation and framing checklists.

What the checklist covers, section by section

The form has seven sections. Each row is answered Yes, No or N/A, every No needs details, and each section has its own photo upload.

SectionWhat you checkA typical No
General InformationBuilding name and address, type and occupancy, occupied or vacant, approximate year built, last inspection date(none: sets context)
Grounds & ExteriorDebris, landscaping, drainage, walkways, exterior lighting, visible address, facade, windows, doors, gutters, pestsStanding water against the foundation on the north side
Roof (visual)Safe access, surface condition, flashings, drains and ponding, sagging, rooftop units secured, interior leak stainsClogged roof drain with ponding over the stairwell
Facility InteriorFloors, walls and ceilings, doors and windows, stairs and rails, elevator, storage, sanitation, signageLoose handrail on the second-floor stair
Fire & Life SafetyExit routes and doors, exit signs, emergency lights, alarm panel, smoke and CO detectors, sprinkler valves, fire pump, extinguisher tags, fire department connection, fire doors, stairwells, evacuation plansFire door propped open with a wedge
Mechanical, Electrical, PlumbingPanel clearance and labels, wiring and GFCIs, lighting, plumbing fixtures, water pressure, water heater, backflow, drains, gas lines, heating, cooling, filters, exhaust fans, flues, thermostatsStorage stacked in front of the electrical panel
Summary & Sign-OffOverall condition, urgent issues, recommended repairs, preventive maintenance notes, date, inspector and owner signatures(records the result)

Several rows carry a specific test. Electrical panels need 36 inches of clear space in front, extinguisher tags should show an inspection within the last 12 months, and smoke detectors should be under ten years old. The section notes point to the references behind the checks, including the International Property Maintenance Code, OSHA's walking-working surfaces rules, the NFPA life safety and sprinkler standards, and the electrical code, so the inspector knows where each line comes from.

Commercial building inspection checklist vs residential

The same template handles both: pick the building type at the top and mark rows that don't apply as N/A. A commercial building inspection checklist runs long in the fire and life safety section, because offices, shops and warehouses tend to have sprinklers, a fire department connection, illuminated exit signs, emergency lighting, posted evacuation plans and sometimes a fire pump or elevator. Backflow testing and rooftop units come up far more often too.

On a house or small apartment building, most of the weight shifts to the roof, drainage, smoke and CO detectors, the water heater and stair rails. Industrial buildings add more exterior storage, heavier electrical rooms and more ways for combustibles to end up where they shouldn't.

How to run the inspection and record it

  1. Pull last year's report and list the open repairs to check first.
  2. Walk outside first, then the roof from safe access only, then each floor from top to bottom, then mechanical and electrical rooms.
  3. Answer every row. A blank is not a Yes.
  4. For every No, write the exact location and the problem, and take a photo that shows both.
  5. Rate the building overall as Good, Fair or Poor and flag any urgent issue.
  6. Turn each repair into a work order with a name and a due date.
  7. Sign it, have the owner or manager acknowledge it, and keep it with last year's.

Mistakes that make inspection records worthless

  • Skipping a year. A gap in the records is the first thing an insurer or buyer notices.
  • No photos. A No without a picture becomes an argument about whether the problem was ever there.
  • No location. Leak stain sends someone hunting; stain on ceiling tile, room 214, below RTU-2 sends them to fix it.
  • Ticking Yes from the hallway. Exit signs, emergency lights and fire doors have to be tested, not looked at.
  • Not rechecking repairs. A work order closed in the office isn't a fix until someone sees it on site.
  • Undated or unsigned reports, which prove nothing about when the building was checked.

Running building inspections on phones in Workyard

In Workyard, the checklist is a digital form the inspector fills in on a phone while walking the building. Photos attach to the row they belong to, the inspector and owner sign on the screen, and the finished report lands back in the office the same day. A failed item can go straight to the person you name, and the hours the crew spends on the repair are tracked against the job. See the construction inspection app.

Get the free building inspection checklist

Download the Building Inspection Checklist as a PDF, Word or Excel file. It is free and there is no sign-up. Print the PDF for a clipboard walk, edit the Word file to add rows for your building, or use Excel to track open repairs from year to year. More checklists for walkthroughs are in site inspection templates.