Ceiling Grid Installation Inspection
1 · Grid Layout
| 1 · Grid Layout | Y | N | N/A | Notes | |
|---|---|---|---|---|---|
| 1.1 | Main runners spaced per project (typically 48″ o.c.) | ||||
| 1.2 | Cross tees centered in openings & openings aligned | ||||
| 1.3 | Main runners straight, level across span | ||||
| 1.4 | Starter / perimeter trim installed plumb & flush | ||||
Photos - Grid Layout · photo refs
2 · Hangers & Wires
| 2 · Hangers & Wires | Y | N | N/A | Notes | |
|---|---|---|---|---|---|
| 2.1 | Hanger wire 12 gauge minimum (or per spec) | ||||
| 2.2 | Wires anchored to structure at proper points | ||||
| 2.3 | Hangers spaced ≤ 48″ along main runners | ||||
| 2.4 | Hangers within 12″ of both ends of each runner | ||||
| 2.5 | Wires plumb, or counter-splayed/braced where more than 1 in 6 out of plumb | ||||
| 2.6 | Wires tied with three tight turns | ||||
Photos - Hangers & Wires · photo refs
3 · Perimeter Trim
| 3 · Perimeter Trim | Y | N | N/A | Notes | |
|---|---|---|---|---|---|
| 3.1 | Angles fastened securely to walls (screws/anchors) | ||||
| 3.2 | Corners mitered or pre-formed with tight joints | ||||
| 3.3 | Trim sits snugly under drywall soffits | ||||
Photos - Perimeter Trim · photo refs