Insulation Inspection Report

Verify insulation installation quality and code compliance with this detailed inspection form. Check R-values, gaps, vapor barriers, and fire blocking before walls are sealed, avoiding costly rework and ensuring proper energy efficiency.

Job
Date

1 · Pre-Inspection Verification

1 · Pre-Inspection VerificationYNN/A
1.1Permits and approved plans available?
1.2Plans reviewed to confirm insulation requirements?
1.3Previous required inspections signed off?
1.4Area is Dried-In?
1.5Code Reference Check

2 · Safety Precautions (OSHA Compliance)

2 · Safety Precautions (OSHA Compliance)YNN/A
2.1PPE in place and in appropriate condition?
2.2Work Area Safe?
2.3Work area offers sufficient heat source clearance?

3 · Exterior Wall Insulation Inspection

Wall Insulation TypeFiberglass battsMineral wool battsBlown-in celluloseBlown-in fiberglassSpray foam (open-cell)Spray foam (closed-cell)Rigid foam board
Installed R-Value (Walls)
Insulation Thickness (inches)

Wall insulation details

Wall insulation detailsYNN/A
3.1Coverage Complete (Walls)
3.2Proper Fit and Sealing
3.3No Compression or Damage
3.4Vapor Retarder Installed (Walls)
3.5Fire Blocking at Walls
3.6Thermal Barrier Installed or Planned Over Foam Plastic (IRC R316.4)

Wall Insulation Photo · photo refs

4 · Ceiling/Attic Insulation Inspection

Ceiling Insulation TypeBlown-in fiberglassBlown-in celluloseFiberglass battsSpray foam
Installed R-Value (Ceiling)
Insulation Depth (Attic) in inches

Roof insulation details

Roof insulation detailsYNN/A
4.1Coverage Complete (Ceiling)
4.2No Gaps or Voids
4.3No Compression
4.4Eave Baffles Installed
4.5Recessed Light Clearance
4.6Attic Access Hatch Insulated
4.7Attic Markers Present Where Appropriate
4.8Ceiling Vapor Barrier Properly Installed
4.9Foam Plastic Covered by Thermal or Ignition Barrier (IRC R316.4, R316.5.3)

Ceiling Insulation Photos · photo refs

5 · Floor and Crawlspace Insulation Inspection

Floor Insulation TypeFiberglass battsMineral wool battsSpray foamRigid board
Installed R-Value (Floor)
Insulation Thickness (in inches)

Floor Insulation Details

Floor Insulation DetailsYNN/A
5.1Coverage Complete
5.2Insulation Supported
5.3No Gaps or Compression
5.4Has Appropriate Ventilation Clearances
5.5Floor Vapor Barrier Properly Installed

Floor Insulation Photo · photo refs

Crawlspace Insulation Location: How is the crawlspace insulated?Floor above crawlspace (vented crawl – insulation in joists above)Crawlspace walls (unvented/sealed crawl – insulation on interior foundation walls)Uninsulated/Not applicable
Crawlspace Wall Insulation TypeRigid foam boardMineral wool batts
Installed R-Value (Crawl Walls)

Crawlspace Insulation Detail

Crawlspace Insulation DetailYNN/A
5.6Coverage Complete
5.7Exposed Insulation Protection
5.8Ground Moisture Barrier Installed Appropriately
5.9Appropriate Crawlspace Ventilation

Crawlspace Photos · photo refs

6 · Final Checks and Comments

6 · Final Checks and CommentsYN
6.1Does the insulation installation meet project requirements and appear code-compliant?
6.2Were any issues or deficiencies found that require correction?

7 · Signature and Project Details

Project ID / Location
Inspector Name
Inspection Date
Name
Signature
Date

Free download

Insulation Inspection Report template: PDF, Word and Excel

Print the form as it is, or download a template you can edit. Every format is free, with no email and no sign-up.

How to use it

How to run the Insulation Inspection Report

  1. 01

    Run it before the work is covered

    Walk it before the next trade closes things up or the area is handed over, and again after any fix. Fill in the header first so the record stands on its own.

  2. 02

    Work the sections in order

    Go through the 7 sections in order so nothing gets skipped. Answer every check: a blank isn’t an answer.

  3. 03

    Every miss gets a photo and an owner

    Write down what’s wrong, take a photo and name the trade that owns the fix, with a date.

  4. 04

    Re-check, sign, then release

    Walk the misses again once they’re fixed. Sign it off, and only then let the area close.

Why we built this

An inspection only counts if it’s written down

A miss found before the work is covered up is a quick fix. Found after, it’s a tear-out, a failed inspection and a schedule hit. The written record is how you prove the check happened.

  • Built for the field. Every check is written the way crews talk, with room for notes, photos and a signature.
  • Free, with no catch. No email, no account. Print it and hand it out.
  • On paper or on the phone. The same form runs on the Workyard app, filed to the job when it’s sent.

3,000+contractors run their crews on Workyard

Meet Workyard

Who we are

Workyard is the construction operations platform for specialty contractors and self-performing general contractors determined to grow without sacrificing job control or margins.

Forms like this one are what our customers’ crews fill in on Workyard every day, on the same app they clock in with.

workers on Workyard every day
100,000+
free templates, none of them gated
182

Forms & Workflows

Get every form back from every crew, every day

  • It shows up on its own. Attach it to a task, a job or clock-out, and it’s on the crew’s phone when it’s due.
  • It can’t be skipped. Make it required and the day can’t close until it’s in.
  • You see it the same day. Filed, flagged or missing, every job on one board, before anyone has to call.

$123,000cut from insurance costs at TR3 Group

More site inspections templates

Free templates for the rest of the job

Browse all templates

Questions

Insulation Inspection Report FAQs

When should an insulation inspection take place?

Inspect insulation after it is installed and before drywall or other finishes cover it. Many jurisdictions that use the IRC or IECC require an insulation inspection at this stage, and it is the last chance to fix gaps, compression and missing vapor retarders. Re-inspect any area that is repaired or reworked before it is closed up.

What should I look for when inspecting insulation?

When inspecting insulation, look for signs of damage or deterioration such as discoloration or damage to the outer jacketing, loose or missing insulation, and any areas where insulation has been removed but not replaced. Check for unsealed penetrations, sagging, or pulling away of jacketing from pipes or supports, and signs of moisture, such as ice, mold, mildew, or condensation on the insulation surface. Also, watch for “hot spots” that might indicate insulation failure and ensure expansion or contraction joints are functioning properly. Additionally, verify that all specified areas are insulated according to the project requirements, including fittings, valves, and equipment. Confirm that insulation materials are approved and properly installed, with seams sealed and vapor barriers intact. Check that metal sheathing, where required, is correctly applied with moisture barrier seam locks, and ensure insulation is secured to prevent contact with vents or other heat sources. Mark any alterations or repairs on as-built drawings for recordkeeping.

Does this form apply to commercial projects?

Yes, this Insulation Inspection Report can be used for both residential and commercial projects. While specific insulation requirements may vary based on building type, occupancy, and local codes, the core elements, such as verifying R-values, proper installation, vapor barriers, and fire blocking, are essential across all project types. For commercial buildings, the form can be adapted to include areas like mechanical rooms, flat roof assemblies, metal framing, or specialized insulation systems.

Is this form required by code?

An Insulation Inspection Report isn’t always required as a formal document. But the inspection itself is a key part of meeting building code. Most jurisdictions, especially those following the International Residential Code (IRC) or International Energy Conservation Code (IECC), require insulation to be inspected before it’s covered by drywall or finishes. This ensures it meets proper R-value, coverage, and installation standards. In commercial settings, insulation inspections help confirm compliance with stricter energy codes, such as ASHRAE 90.1, and are often tied to permitting or energy efficiency certifications. While inspectors may not ask for a specific report form, having one ready can simplify approvals, reduce rework, and help you clearly document that the job meets code requirements.

Do I need a Workyard account to use it?

No. Print the paper form, save it as a PDF, or download the Word or Excel file, free, with no email and no sign-up. You only need an account to put the digital form on your crew’s phones.

Can I edit the template?

Yes. Download the Word or Excel version to add your logo, add checks from your project spec or remove sections you don’t need. They open in Google Docs and Google Sheets too.

How do I get my crew to fill it in on their phones?

Add the digital form to Workyard and attach it to the job or the task it belongs to. It shows up in the app your crew already clocks in with, and every form comes back signed, with its photos, filed to the job.

Trigger the form at the right moment

A job's Forms tab in Workyard: each form, the clock-in or clock-out that triggers it, and how many have been submitted
A van check filled in on the Workyard app: the damage photo, a description and the tech's signature, ready to submit