Free template · paper and digital

Concrete Strength Test Record

Tracks concrete cylinders from sampling and curing through capping and break results, so compressive strength is on file for every pour.

WordExcel
  • No email
  • No sign-up
  • Edit it, add your logo
See every check

The template

The full Concrete Strength Test Record

Print it for the clipboard, or put it on your crew’s phones. Same 10 checks either way.

Your logo

Concrete Strength Test Record

The free Concrete Strength Test Record guides technicians through logging sample IDs, molding and curing details, break loads, average strengths, and acceptance checks. It takes inspiration from ASTM C39 compression tests, ASTM C31 curing practices, ASTM C1231 unbonded capping, and ACI 318 acceptance limits to create one easy-to-use field document.

Job
Date
Project Name
Location / Element
Batch Ticket No.
Sampling Date / Time
Ambient Temp (°F)

1 · Sampling

1 · SamplingYNN/A
1.1Sample taken from discharge stream at continuous rate
1.2Sample taken from the middle portion of the load (not the first or last discharge); molding started within 15 min
1.3Sample container clean and moisture-tight
1.4Cylinders rodded per C31 (6×12 in: 3 layers; 4×8 in: 2 layers; 25 strokes per layer; sides tapped 10–15 times)

Photos - Sampling · photo refs

2 · Molding & Curing

Inspection

Cylinder IDsMolded Date/TimeInitial Curing LocationCuring Box IDBox Temperature (°F)Note

Photos - Molding & Curing · photo refs

3 · Cap Method

3 · Cap MethodYNN/A
3.1Neoprene pad type / lot #
3.2Pad thickness per spec
Pads and retainers centered; pad hardness suits strength range per C1231YesNoN/A

Photos - Cap Method · photo refs

4 · Break Data

Break Data Items

Cylinder IDBreak Age (days)Break Date/TimeMachine IDLoad at Failure (kips)Strength (psi)Failure ModeAccept (Y/N)Note

Photos - Break Data · photo refs

5 · Acceptance & Follow-Up (ACI 318 §26.12)

Specified f′c (psi)

Inspection

InspectionYN
5.1Each strength test (average of the cylinders broken at test age) ≥ f′c − 500 psi (f′c ≤ 5,000 psi) or ≥ 0.90 f′c (f′c > 5,000 psi)? (If “No,” add details in Notes)
5.2Average of any three consecutive strength tests ≥ f′c? (If “No,” add details in Notes)
5.3Additional tests required (if yes, specify action in notes)
5.4Core tests per ASTM C42 scheduled (if yes, input date in notes)

6 · Sign Off

Sampler

Name
Signature
Date

QA Technician (if different)

Name
Signature
Date

Lab Supervisor

Name
Signature
Date

Owner / Engineer of Record

Name
Signature
Date

References & Standards

  • ASTM C172 – Sampling fresh concrete
  • ASTM C31 – Making & curing cylinders
  • ASTM C1231 – Unbonded capping pads
  • ASTM C39 – Compressive-strength test
  • ASTM C138 – Density/unit weight check
  • ASTM C42 – Core strength tests
  • ACI 318-19 §26.12 – Strength acceptance limits

Your AHJ and the code edition it has adopted govern. This checklist supports your inspection; it doesn’t replace the one your jurisdiction requires.

Free download

Concrete Strength Test Record template: PDF, Word and Excel

Print the form as it is, or download a template you can edit. Every format is free, with no email and no sign-up.

How to use it

How to run the Concrete Strength Test Record

  1. 01

    Check it at the hold point

    Run it before the next trade covers the work, against the plans and the spec.

  2. 02

    Work the sections in order

    Go through the 6 sections in order. Measure where it asks for a number; don’t eyeball it.

  3. 03

    Log every miss with a photo

    Write down what doesn’t meet spec, who fixes it and by when, and attach a photo.

  4. 04

    Sign off when it’s right

    Re-check the fixes, then sign. The signed sheet is your proof the work met spec when it was built.

Why we built this

Rework is the most expensive work you’ll do

A miss caught at the hold point is a quick fix. Caught after the next trade has covered it, it’s a tear-out, a delay and a margin gone.

  • Built for the field. Every check is written the way crews talk, with room for notes, photos and a signature.
  • Free, with no catch. No email, no account. Print it and hand it out.
  • On paper or on the phone. The same form runs on the Workyard app, filed to the job when it’s sent.

3,000+contractors run their crews on Workyard

Meet Workyard

Who we are

Workyard is the construction operations platform for specialty contractors and self-performing general contractors determined to grow without sacrificing job control or margins.

Forms like this one are what our customers’ crews fill in on Workyard every day, on the same app they clock in with.

workers on Workyard every day
100,000+
free templates, none of them gated
182

Forms & Workflows

Get every form back from every crew, every day

  • It shows up on its own. Attach it to a task, a job or clock-out, and it’s on the crew’s phone when it’s due.
  • It can’t be skipped. Make it required and the day can’t close until it’s in.
  • You see it the same day. Filed, flagged or missing, every job on one board, before anyone has to call.

$123,000cut from insurance costs at TR3 Group

More quality control templates

Free templates for the rest of the job

  • Quality Control

    Concrete Pour Log

Browse all templates

Questions

Concrete Strength Test Record FAQs

When is a Concrete Strength Test Record required?

A Concrete Strength Test Record is needed whenever cylinders are cast for acceptance-typically every 150 yd³ or once per day, per ACI 301. It proves that each batch met design strength and that all breaks were performed under ASTM C39 rules.

What data must the Concrete Strength Test Record capture?

The Concrete Strength Test Record logs sample time, cylinder IDs, curing method, cap type, break age, load, strength, and acceptance calculation. It also notes air, density, and temperature if specified, creating a complete audit trail that aligns with ASTM and ACI requirements.

Who should sign the Concrete Strength Test Record?

Field technicians enter results, but a certified laboratory manager or licensed professional engineer reviews and signs the record. Their signature, license or certification number, and date verify that sampling, curing, and testing fully complied with ASTM C39 and project specifications.

What if a test fails acceptance in the Concrete Strength Test Record?

If an average strength or single break falls below ACI 318 limits, mark the test in red, notify the engineer, and consider cores per ASTM C42. The Record documents corrective actions-mix review, retest schedule, or structural evaluation-for future liability protection.

Do I need a Workyard account to use it?

No. Print the paper form, save it as a PDF, or download the Word or Excel file, free, with no email and no sign-up. You only need an account to put the digital form on your crew’s phones.

Can I edit the template?

Yes. Download the Word or Excel version to add your logo, add checks from your project spec or remove sections you don’t need. They open in Google Docs and Google Sheets too.

How do I get my crew to fill it in on their phones?

Add the digital form to Workyard and attach it to the job or the task it belongs to. It shows up in the app your crew already clocks in with, and every form comes back signed, with its photos, filed to the job.

Trigger the form at the right moment

A job's Forms tab in Workyard: each form, the clock-in or clock-out that triggers it, and how many have been submitted
A van check filled in on the Workyard app: the damage photo, a description and the tech's signature, ready to submit

Book a demo with a Workyard specialist

Your local Workyard specialist

Works with 50 contractors across the US

Your details

30 min · Video call