An attic inspection checklist turns a flashlight crawl through the attic into a written record: framing and sheathing, insulation type and depth, ventilation, signs of leaks, ductwork and wiring, pests, and who is going to fix what. Builders, home inspectors, roofers, HVAC techs, insulation contractors and property managers use it on new homes before closeout, on remodels, after a roof leak, and on energy upgrades. Each section has its own photo upload, so the office sees what the inspector saw.

What the attic inspection checklist covers

The form has nine sections:

SectionWhat gets recorded
Header informationWeather, safe access confirmed, ladder secure and inspected, PPE used, photo of the access setup
Framing and sheathingStains, sagging or bowing, cracks or warping, mold
Insulation checkType, even coverage, depth at the hatch and at a rear corner, estimated R-value, insulation blocking vents, gaps, vermiculite present
VentilationSoffit vents clear, exhaust vents present, moisture at vents, estimated net free vent area, balance
Moisture and leak evidenceDrips or wet spots, rusted nails, torn vapor barrier, mold odor or patches
HVAC and electricalDisconnected or leaking ducts, flue clearances, open junction boxes, light fixtures covered, unsealed penetrations, bath, kitchen or dryer exhaust dumping into the attic
Pests and housekeepingDroppings, gnawing, nests, insects, stored items blocking airflow, debris
SummaryFindings, trade assigned, target date, urgency, extra photos
FinalizationInspector name, date and signature

The insulation and ventilation sections are tied to the 2021 IRC and IECC, and the ventilation section to IRC R806. Your jurisdiction may have adopted a different edition, so check local code for required R-values and vent area.

How to record insulation and ventilation

Measure insulation depth in two places, at the access hatch and at a far corner. Depth near the hatch is often fine because it is the easiest spot to fill, while corners and eaves are where blown insulation runs thin. Note the type, then estimate the R-value from depth and type where you can.

For ventilation, check that the soffit vents are not buried under insulation, that there is a matching exhaust at the ridge, gable or a fan, and that there is no frost, staining or mold around the vents. Write down your estimate of net free vent area if you can see the vent labels.

Mark vermiculite if you see it. The form says not to disturb it, since it may contain asbestos, and the fix belongs to a qualified abatement contractor.

Assign each finding to a trade

The summary is what makes this attic inspection useful after you climb down. Assign each finding to a plumber, electrician, carpenter, HVAC tech or roofer, set a target date and an urgency level, and attach photos. A bath fan venting into the attic goes to HVAC; rusted nails and stained sheathing go to the roofer.

Run it on a phone or download it free

In Workyard the checklist runs as a digital inspection form on the inspector's phone, with photos for each section, a signature on screen, urgent findings flagged to a named person, and every report filed to the job for PDF or CSV export. Pair it with the insulation inspection report and the roof inspection checklist. You can also download it free as a PDF, Word or Excel file, no sign-up needed.